Product Description
- FOR WCC1400R (Remote Cooled)
- SYSTEM SECTION: Electrical Box
This component is an important safety control device used to regulate the timing sequence between the compressor and the gear motor-auger assembly. Its primary purpose is to prevent mechanical damage caused when ice solidifies into a hard-block before the auger can do its job. A defective part may result in a snapped auger and/or a burned out gear motor.
Note: This component is only identified for use on the WCC1400R (remote cooled) model in the parts manual. Oddly, other resources show this part used on other WCC models even though it doesn’t show in their respective parts manuals. Since there is no official documentation provided by the manufacturer, we can’t confirm usage on those models.
We may not have stock at the time of purchase. Upon ordering it, we will check availability and respond back if an issue exists. This part may require a special order and a lead time.