Product Description
- FOR CIM1446 (R404-R449)
- FOR CIM1447 (R404-R449)
- FOR CIM2046 (R404-R449)
- FOR CIM2047 (R404-R449)
- SYSTEM SECTION: Water System
- VOLTAGE: 230V/60HZ
- USED W/ OEM # 9051782-36 (Wtr In Tube) (non-stocked)
- USED WITH OEM # 9051739-01 (In/Out Bracket)
This water inlet valve serves to fill the water sump basin with fresh water. It is engaged each time the freeze cycle starts or after a purge cycle. This activation occurs when the control board sends a signal to the valves electromagnetic solenoid coil. This in turn causes a magnetic force to lift an internal plunger thus opening the valve. Fresh water then flows into the sump tray. Once it is full, a signal is relayed back to the control board which then routes voltage back to the water valve to snap the plunger closed. Thus, the water flow stops.








