Product Description
- FOR ALL CIM MODELS (R404, R290 & R449 versions)
- FOR CIM1446 (R404 & R449) USE RIGHT SIDE
- FOR CIM1447 (R404 & R449) USE RIGHT SIDE
- FOR CIM2046 (R404 & R449) USE RIGHT SIDE
- FOR CIM2047 (R404 & R449) USE RIGHT SIDE
- SYSTEM SECTION: Refrigeration System
- RH = RIGHT HAND
- IF CIM1446 or CIM2046
- USE OEM # 9041098-03 (Left side switch)
This HT safety switch functions as a critical safety cutoff switch. The component is attached or clipped directly to the copper refrigeration discharge line for the purpose of monitoring temperature. If the thermal temp exceeds safe operating parameters, an internal bimetal disc in the sensor bulb snaps open. With the circuit open, the hot compressor immediately shuts off. This action is intended to prevent major damage to the compressor. Since the CIM1446, CIM1447, CIM2046, and CIM2047 have two evaporators, it has two safety switches. This component is specifically used on the right side with part # 9041098-03 used on the left side. Both switches function the same for the same reasons.








